Sunlogic Electrical Appliance Limited
Main products:UPS,AVR,AVS,Inverter,Battery Charger
Products
Contact Us
  • Contact Person : Mr. Feng Jason
  • Company Name : Sunlogic Electrical Appliance Limited
  • Tel : 86-760-2638988, 2636888
  • Fax : 86-760-2638788
  • Address : Guangdong,Zhongshan,Dongfu 3rd Road, Dongfeng Town
  • Country/Region : China
  • Zip : 528425

Line Interactive & Sine Wave UPS

Line Interactive & Sine Wave UPS
Product Detailed
Line Interactive & Sine Wave UPS. Microprocessor Control. Auto Charge & High Frequency Charge. 50/60Hz Auto Adjust.
Model No.MCU-500NSMCU-1000NSMCU-1500NSMCU-2000NSMCU-3000NS
Rated Power300W600W900W1200W2400W
INPUTVoltage140V---275VAC
Frequency45--65Hz
OUTPUTVoltage220V ±3(Inverter Mode) / 220V±10(Utility Mode)
Frequency50/60±0.05Hz (Automaitc transfer according to the frequency of utility power )
WaveformSine Wave
Utility PowerUtility Mode with AVR Function
Cold Start Power100% of Rated Power (for 220V Lamp)
BATTERYTypeSealed Lead-Acid, Maintenance-free
DC Voltage12VDC24VDC48VDC
Capacity12V/7AH12V/7AH*212V/9AH*212V/7.2AH*412V/9AH*4
Back-up Time(Half/Full Load)≥2/6≥2/6≥2/6≥2/6≥2/6

Value of Low Voltage Protection

11V+/-0.2V22V+/-0.5V42V+/-0.5V

Value of Under Voltage Protection

10V+/-0.2V21V+/-0.5V41V+/-0.5V
Charging Voltage13.8V+/-0.2V28V+/-0.5V55.5V+/-0.5V
Charging Current0.5-0.8A0.5-1.0A0.5-1.0A0.5-1.0A1.0-1.2A
Recharge Time≤8Hours.Charging up to 90%

Reverse 

Connection

No startup
Charging ModeAutomatic charging while power off & accessing to utility power
Transfer Time< 5ms< 5ms< 5ms< 5ms< 5ms
AUDIBLE ALARM

Utility Power Normal

No alarm

Battery 

Discharge

Beeping sound every 30 seconds after utility power fails

Beeping sound every 30 seconds 

after utility power fails.Keep pressing the Silent Function Button for 2 seconds for muteness.

Beeping sound every second for low voltage alarm
FaultTurn to Battery Mode without output, continiuous beep for 20 seconds then automatically shutdown
PROTECTIONOverload ProtectionBattery Mode: Overload 125%: continuous beeping, cut down the output after 30 seconds & shutdown after another 20 seconds.Overload above 150%: immediate protecting. /Utility Mode: continuous beeping without protection. 
Low Voltage ProtectionAutomatically shutdown, return to normal mode after utility power accessed
High Tempreture ProtectionTurn to Battery Mode, shutdown while Inner tempreture be up to 90
Short Curcuit ProtectionAutomatically cut down the output & shutdown after 20 seconds
On/Off ModeON: Keep pressing the On-off button for 2 seconds for startup.Automatically start without pressing the ON button while accessing to utility power.  
OFF: Keep pressing the On-off button for 2 seconds for shutdown.Battery be charged normally with UPS cutting down the output while accessing to utility power.
Cooling SystemThermostatic Control Fan
IndicatorsLCD
COMMUNI-CATIONPortRs232/USB
InterfaceMonitor of Utility Fault,Power Failure,Battery,UPS Statu Indicator etc.

Software Function

1.Anlysis of Power Status, 2.Timing Controlling, 3.Monitor UPS, 4.Execute UPS Self-diagnosis, 5.Automatic Save
Noise(dB)< 35dB< 40dB< 45dB
Operating Temperature0~40
Relative Humidity20% ~ 90% non-condensing
Dimension(mm)155*85*330195*120*300145*410*220192*460*340192*460*340
Net Weight(Kg)6.50 13.20 16.50 29.00 32.00 

Line Interactive & Sine Wave UPS



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.